ZEUS Á¤¹Ð ÇÇÆêÆÃ ¸ðµâ
|

|
[ZEUS Air Displacement Pipette Modules]
|
|
 |
¾×ü·¹º§°¨Áö(Liquid Level Detection, LLD)
|
¼ººÐÇÇÆê¸ð´ÏÅ͸µ±â¼ú(Qualitative Pipette Monitoring, QPM)
|
¾×Àû»ý¼º¹æÁöÁ¦¾î±â¼ú(Anti-Droplet Control, ADC)
|
Àüµµ¼ºÇÇÆêÆÁ(Tip Presence Senser)
|
|
|
|
|
|
|
°³
¿ä
|
Intelligent Liquid Handling For Better Results
|

|
ÀåºñÁ¦Á¶¾÷ü´Â Á¾Á¾ ±×µéÀÇ ¾×üÁ¶ÀÛÀÇ ¿ä±¸Á¶°ÇÀ» ³Ê¹« °ú¼ÒÆò°¡ÇÏ´Â °æ¿ì°¡ ÀÖ¾î ºñ¿ëÃʰú, Á¦Ç°ÀÇ Àç¼³°è, Ãâ½ÃÁö¿¬ µîÀÌ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù. ±Þ°ÝÇÏ°Ô º¯ÈÇÏ´Â ÃÖ÷´Ü »ê¾÷¿¡¼ ½ºÇǵåÀÇ Â÷À̷ηΠ½ÃÀåÀ» ¼±µµÇÒ ¼ö ÀÖ°í ȤÀº Á¦Ç°Ãâ½Ã¿¡ ½ÇÆÐÇÒ ¼öµµ ÀÖ½À´Ï´Ù. ZEUS·Î °í°´ÀÇ ÇÁ·ÎÁ§Æ®¸¦ Á¤È®ÇÑ ½Ã°£°ú ¿¹»ê¿¡ ³¡³¾ ¼ö ÀÖµµ·Ï ÃÖÀûÀÇ ÆÄÆ®³Ê°¡ µÇ¾î µå¸®°Ú½À´Ï´Ù |
ZEUS Excellence Comes Standard
|
ÀϹÝÀûÀ¸·Î ÇÇÆêÆÃ ºÎǰ°ú ºÎǰÁ¦ÀÛ»çµéÀº Á¤È®µµ¿Í Á¤¹ÐµµÀ§ÇØ ºÎǰÀ» ÅëÇÕÇØ¾ß ÇÏ´Â ºÎ´ãÀ» °¡Áö°í ÀÖÁö¸¸, Hamilton´Â »ê¾÷À» ÁÖµµÇÏ´Â ÇÇÆêÆÃ±â¼úÀÎ °ø±âº¯À§ÇÇÆêÆÃ(Air Displacement Pipetting, ADP) ¸ðµâÀ» °³¹ßÇÏ¿© STAR¢â liquid handler¿¡ ÀåÂøÇÏ¿© ½ÃÆÇÇϰí ÀÖ½À´Ï´Ù.
ZEUS´Â ÈíÀÔ¸í·ÉÀ» ÁÖ¾úÀ» ¶§, Ç÷±Á® µå¶óÀ̺ê´Â ¼³Á¤µÈ °Å¸®º¸´Ù ´õ ¸¹ÀÌ À̵¿ÇϰԵ˴ϴÙ. ZEUS´Â ¾×üǥ¸éÀ» Áö´ÉÀûÀ¸·Î °¨ÁöÇÏ¿©(Liquid Level Detection, LLD) ¿ë±âÀÇ Çü»ó¿¡ µû¶ó »ý±â´Â ¸Þ´Ï½ºÄ¿½º(maniscus)¸¦ µû¶ó ÇÇÆêÆÁÀÌ ³»·Á°¡¸é¼ ½Ã·á¸¦ ÈíÀÔÇϸç, ÈíÀԵǴ ¾×üÀÇ Á¾·ù¿¡ µû¶ó ¼Óµµ¿Í Ç÷±ÀúÀÇ ¿òÁ÷ÀÓÀ» Á¶Á¤ÇÕ´Ï´Ù. ZEUS´Â ½Ã·á ÈíÀԽà ¹è¾Ð µ¥ÀÌÅ͸¦ ¾Ë·ÁÁÖ´Â ´ë½Å ÇÇÆêÆÁÀÌ ¸·È÷°Å³ª ±âÆ÷°¡ ÈíÀԵǴ °ÍÀ» °¨ÁöÇÏ¿© ¾Ð·Â ÆíÂ÷¸¦ Àû±ØÀûÀ¸·Î ¸ð´ÏÅ͸µÇÕ´Ï´Ù. ÀÌ·¯ÇÑ ³ôÀº ¼öÁØ ±â´ÉµéÀº °í°´µéÀÇ °³¹ß ÀÏÁ¤À» Å©°Ô ´ÜÃàÇϰí
½Å¼ÓÇÏ°Ô ½ÃÁ¦Ç°À» Ãâ½ÃÇÏ¿© ³ôÀº ¼öÀÍÀ» âÃâÇÒ ¼ö ÀÖµµ·Ï ÇÕ´Ï´Ù. |
Air Displacement Pipetting Module |
Hamilton ZEUS (Z-Excursion Universal Sampler)´Â ¿Ïº®ÇÏ°Ô ÀÚµ¿ÈµÇ¾î ÀÖ°í ÇÊ¿äÇÑ ±â´ÉÀÌ ¸ðµÎ Æ÷ÇԵǾî ÀÖ¾î¼ Áø´ÜÀåºñ ¹× »ý¸í°úÇÐÀåºñ¿Í ÅëÇÕÇÏ¿© ¹Ù·Î »ç¿ëÇÒ ¼ö ÀÖ´Â ÇÇÆêÆÃ ¸ðµâÀÔ´Ï´Ù. HamiltonÀÇ Çõ½ÅÀûÀÎ °ø±âº¯À§ÇÇÆêÆÃ±â¼ú(Air Displacement Pipetting, ADP)±â¼úÀ» ±â¹ÝÀ¸·Î Çϰí ÀÖÀ¸¸ç, ij¸®¿À¹ö-½Ã·á°¡ ³ÑÄ¡´Â °ÍÀ» ¹æÁöÇÒ ¼ö ÀÖ´Â ÀÏȸ¿ë ÇÇÆêÆÁ(CO-RE¢â)À» »ç¿ëÇÕ´Ï´Ù. ÇÇÆêÆÃ ¸ðµâÀº Á¤È®µµ¿Í ¾ÆÀüÇÑ ÇÇÆêÆÃÀ» º¸ÀåÇÏ´Â ¼ººÐÇÇÆê¸ð´ÏÅ͸µ±â
(Qualitative Pipette Monitoring, QPM)ÀÌ ÀåÂøµÇ¾î ÀÖ½À´Ï´Ù. |
More than just a component
|
Hamilton ZEUS (Z-Excursion Universal Sampler)´Â Àü¹ÝÀûÀÎ ÇÇÆêÆÃ °úÁ¤À» ¼öÇàÇÒ ¼ö ÀÖµµ·Ï °í¾ÈµÇ¾ú½À´Ï´Ù. ZÃàÀ» ÀÌ¿ëÇÏ¿© ÀÚµ¿À¸·Î ÆÁÀ» ÁýÀ» ¼ö ÀÖÀ¸¸ç ¾×ü·¹º§À» °¨ÁöÇÏ¿© ¾×ü¸éÀ» µû¶ó ÈíÀÔ°ú ÅäÃâÀ» ÇÒ ¼ö ÀÖ½À´Ï´Ù. ZEUS´Â Á¤È®Çϰí Á¤¹ÐÇÑ ÇÇÆêÆÃÀ» º¸ÁõÇϱâ À§ÇØ ¾×ü Á¾·ù¿¡ µû¶ó ÇǽºÅæÀÇ ¿òÁ÷ÀÓÀ» Á¶Á¤ÇÕ´Ï´Ù. ZEUS¿¡ žÀçµÈ ¼ººÐÇÇÆê¸ð´ÏÅ͸µ±â¼ú(Qualitative Pipette Monitoring, QPM) ±â´ÉÀº ¿ÀÀÛµ¿À» ¿¹¹æÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ·¯ÇÑ
³ôÀº ¼öÁØÀÇ ±â´ÉÀº °í°´¿¡°Ô °³¹ß ÀÏÁ¤À» ´ÜÃàÄÉ ÇÏ¿© ºü¸¥°Ô Á¦Ç°À» Ãâ½ÃÇÒ ¼ö ÀÖµµ·Ï ÇÕ´Ï´Ù. |
Disposable Tips
|
HamiltonÀº ÀϹÝÀûÀ¸·Î »ç¿ëµÇ´Â ÀÚµ¿È Àåºñ¿¡ »ç¿ëÇÒ ¼ö ÀÖµµ·Ï ´Ù¾çÇÑ Á¾·ùÀ§ ÇÇÆêÆÁÀ» °ø±ÞÇϰí ÀÖ½À´Ï´Ù. Àüµµ¼º ¶Ç´Â ºñÀüµµ¼º ÇÇÆêÆÁ, ¼¼Ã´°¡´ÉÇÑ ÇÇÆêÆÁ, °¡´Ã°í ŒóÀ» ¼ö ÀÖ´Â »ÏÁ·ÇÑ ÇÍÆêÆÁÀº »óÀÌÇÑ º¼·ý°ú Æ÷ÀåÀ¸·Î ´Ù¾çÇÏ°Ô °ø±ÞµË´Ï´Ù. |

|
|
|
|
Ư
¡ |
Obtaining Accuracy through Air displacement
pipetting
|
°ø±âº¯À§ÇÇÆêÆÃ(Air Displacement Pipetting, ADP)Àº
ÇǽºÅæÀ» »ç¿ëÇÏ¿© »ç¿ëÇϰíÀÚ ÇÏ´Â ¾×ü¸¦ ÀÏȸ¿ë ÇÃ¶ó½ºÆ½ ÆÁÀ¸·Î ÈíÀÎÇÕ´Ï´Ù. ÇǽºÅæÀÌ À§·Î À̵¿ÇϰÔ
µÇ¸é, ÆÁ¾È¿¡ ÀÖ´Â °ø±â¾ÐÀº ³·¾ÆÁö°í »ùÇÃÀº ±â¾ÐÂ÷¿¡ ÀÇÇØ ÆÁÀ¸·Î µé¾î¿À°Ô
µË´Ï´Ù. ÀÌ·¯ÇÑ ÇÇÆêÆÃ ¹æ¹ýÀº ½Ã·áÀÇ ±³Â÷¿À¿°À» ÃÖ¼ÒÈ ÇÒ ¼ö ÀÖµµ·Ï
´ÜÁö
ÇÇÆêÆÁ¸¸
Á¢ÃËÇÕ´Ï´Ù.
ZEUS
ÇÇÆêÆÃ
¸ðµâÀº
¾×üº¯À§ÇÇÆêÆÃ½Ã½ºÅÛ(Liquid Displacement Pipetting, LDP)¿Í
ºñ±³ÇßÀ» ¶§ ¼º´ÉÇâ»ó ¹× À¯Áöº¸½º¸¦ ÃÖ¼ÒÈÇÒ ¼ö ÀÖµµ·Ï °íü»óÅÂÀÇ ÇǽºÅæÀ» »ç¿ëÇϰí ÀÖ½À´Ï´Ù. |
What are the Challenges with Air
Displacement Pipetting?
|
°ø±â´Â ¾ÐÃàÀÌ µÇ±â ¶§¹®¿¡ ¸ðµç º¯¼ö°¡ °í·ÁµÇÁö ¾Ê°í ÀûÀýÈ÷
º¸Á¤µÇÁö ¾ÊÀº °æ¿ì¿¡´Â ¹®Á¦°¡ ¹ß»ýÇϰí ÇÇÆêÆÃÀÇ Á¤È®µµ¿Í Á¤¹Ðµµ¸¦ ¸¸Á·½ÃŰ±â°¡ ¾î·Á¿öÁý´Ï´Ù. ¹Ðµµ, Ç¥¸é Àå·Â, Èֹ߼º, Á¡µµ µî°ú °°Àº ¾×üƯ¼ºµé ¶ÇÇÑ ÇÇÆêÆÃ Á¤È®µµ¿¡ ¿µÇâÀ» ¹ÌĨ´Ï´Ù. ´ÙÇàÈ÷µµ ZEUS ä³ÎÀº ÀÌ·¯ÇÑ ¿ä¼ÒµéÀ» ¹Ý¿µÇÏ¿© ¼öÇàÇϵµ·Ï ¼³°èµÇ¾ú½À´Ï´Ù. ´ÜÁö ÆÄ¶ó¹ÌÅÍÀÇ ÀԷ¸¸À¸·Î ZEUS´Â ÇÇÆêÆÃ ÀÛ¾÷À» ÁøÇàÇϸç Á¤È®ÇÑ ¾Ð·Â ¼öÄ¡¸¦ Ȱ¿ëÇÏ¿© ¿øÇϽô ´ë·Î ÈíÀÔ°ú ÅäÃâÀ» Á¶ÀýÇÒ ¼ö ÀÖ½À´Ï´Ù. ¸¸¾à »ç¿ëÀ¯Ã¼¿¡ ´ëÇÑ ÀûÀýÇÑ º¯¼ö°¡ ¾Ë·ÁÁ®
ÀÖÁö
¾Ê´Ù¸é
Hamilton¿¡¼´Â
±× ¾×ü¿¡
´ëÇÑ
ºÐ·ùÇϰí
ÀÎÁõÇÒ
¼ö ÀÖµµ·Ï
µµ¿Í
µå¸±
°ÍÀÔ´Ï´Ù. |
The
Power
of Qualitative
Pipette
Monitoring
(QPM)
|
STAR
Liquid
Handling
PlatformÀ»
ÅëÇØ
Hamilton˼
¾Ð·Â
°î¼±À»
Áö´ÉÇü
µ¿ÀÛÀ¸·Î
º¯È¯ÇÏ´Â
¹æ¹ýÀ»
ã¾Æ³Â½À´Ï´Ù.
ZEUS¸¦
»ç¿ëÇϸé
ÀÌ·¯ÇÑ
ÀåÁ¡À»
¸ðµç
¾×ü
ó¸®
¾ÖÇø®ÄÉÀ̼ǿ¡
Àû¿ëÇÒ
¼ö ÀÖ½À´Ï´Ù.
¾Ð·Â
µ¥ÀÌÅ͸¦
Ȱ¿ëÇÒ
¼ö ÀÖ´Â
Ÿ»çÀÇ
ÇÇÆêÆÃ
¸ðµâÀÌ
ÀÖÁö¸¸
¿ÀÁ÷
ZEUS¸¸ÀÌ
µ¥ÀÌÅ͸¦
ÇØ¼®Çϰí
½ÇÇà
°¡´ÉÇÑ
Á¤º¸¸¦
´Ù½Ã
½Ã½ºÅÛ¿¡
Àû¿ëÇÒ
¼ö ÀÖ½À´Ï´Ù.
|
Clogged Tip Detection |
Insufficient Liquid Detection |
|

|
If the tip clogs
during aspiration the
pressure will spike
down. As the plunger
moves, sample is not
being aspirated to help
equalize the pressure.
|
If there is insufficient
liquid in the tube,
the pressure curve will
start down as normal
but then will return
to a pressure much higher
than the expected level
represented by ¥Äp in
the graph. The higher
pressure is a result
of having less liquid
in the tip due to an
incomplete aspiration.
|
Aspiration of Foam |
Droplet Prevention
|

|

|
If ZEUS pipettes
foam instead of liquid,
the pressure sensor
detects spikes during
the aspiration. Based
on the severity of the
spikes, a threshold
can be set for a failed
aspiration.
|
Volatile liquids
like acetone and methanol
can be extremely difficult
to pipette using air
displacement. These
liquids tend to vaporize
in the tip which raises
the air pressure resulting
in liquid dripping from
the tip. ZEUS is equipped
with Anti-Droplet Control
(ADC). When enabled,
the pressure is monitored
in the tip. As the pressure
rises, the piston is
retracted to equalize
the pressure and prevent
dripping. The illustrations
show the pressure curve
when ADC is on and off.
|
ZEUS
and
ZEUS
LT Pipetting
Channels
|
ZEUS ä³ÎÀº µ¶¸³Çü ÇÇÆê ä³ÎÀÎ ZEUS LT¿Í ÅëÇÕÇü ZÃà°ú ÇÔ²²
ÀÖ´Â
ZEUS·Î
±¸¼ºµÇ¾î
ÀÖ½À´Ï´Ù.
¸ðµç
ZEUS
ä³ÎÀº
ÇÇÆêÆÃÀ»
À§ÇÑ
ÇÊ¿äÇÑ
±â´ÉÀÌ
žÀçµÈ
µ¶¸³Çü
¾×ü󸮸ðµâ·Î¼
°èÃø±â¿¡
ÅëÇÕµÉ
¼ö ÀÖ½À´Ï´Ù.
ZEUS
ÇÇÆêÆÃ
¸ðµâÀº
HamiltonÀÇ
Çõ½ÅÀûÀÎ
°ø±âº¯À§ÇÇÆêÆÃ
±â¼ú°ú(Air
Displacement
Pipetting,
ADP)
CO-RE¢â
(Compressed
O-ring
Expension)
ÆÁÀ»
Ȱ¿ëÇÕ´Ï´Ù. ZÃàÀÌ
³»ÀåµÈ
ZEUS°¡
¸í·ÉÀ»
¹Þ°í
ÈíÀÔÇÒ
¶§ Ç÷±Àú
µå¶óÀ̺긦
¼³Á¤µÈ
°Å¸®¸¸Å
´Ü¼øÈ÷
À̵¿½ÃŰ´Â
°Í »Ó¸¸
¾Æ´Ï¶ó
±× ÀÌ»óÀ»
¼öÇàÇÕ´Ï´Ù.
ZEUS´Â
¿ë¾×ÀÇ
Ç¥¸éÀ»
Á¤È®ÇϰÔ
ÆÇ´ÜÇϰí,
¿ë±âÀÇ
¸ð¾ç¿¡
»ó°ü¾øÀÌ
ÆÁÀÇ
À§Ä¡¸¦
Á¶ÀýÇϸç
¾×ü¸¦
ÈíÀÔÇÕ´Ï´Ù.
¶ÇÇÑ,
Ç÷±ÀúÀÇ
¼Óµµ¿Í
¿òÁ÷ÀÓÀ»
Á¤È®ÇϰÔ
Á¦¾îÇÏ¿©
ÈíÀԵǴÂ
¾×ü
¿ÀÂ÷¸¦
º¸Á¤ÇÕ´Ï´Ù.
ZEUS´Â
´Ü¼øÈ÷
ÈíÀÔ
Áß¿¡
¿ª¾Ð
µ¥ÀÌÅ͸¸
º¸°íÇÏ´Â
´ë½Å,
ÆÁÀÌ
¸·È÷°Å³ª
°ø±â
ÈíÀÔÀÇ
Á¤µµ¸¦
³ªÅ¸³¾
¼ö ÀÖ´Â
¾Ð·ÂÀ»
´Éµ¿ÀûÀ¸·Î
¸ð´ÏÅ͸µÇÕ´Ï´Ù.
ÀÌ·¯ÇÑ
³ôÀº
¼öÁØÀÇ
±â´ÉÀ»
ÅëÇØ
°í°´Àº
°³¹ß
ÀÏÁ¤À»
Å©°Ô
´ÜÃàÇϰí
Á¦Ç°À»
º¸´Ù
ºü¸£°Ô
Ãâ½ÃÇÏ¿©
¼öÀÍÀ»
º¸´Ù
ºü¸£°Ô
°¡Á®¿Ã
¼ö ÀÖ½À´Ï´Ù.
|
Pipette Tips for Any Application
|
HamiltonÀº ÀÚµ¿È °ü·Ã ¹®Á¦¸¦ ÇØ°áÇϱâ À§ÇÑ ´Ù¾çÇÑ ÇÇÆêÆÁÀ»
Á¦°øÇÕ´Ï´Ù. Àüµµ¼º, ºñÀüµµ¼º, ½½¸²Çü ¹× ÇǾî½Ì ÆÁ µî ´Ù¾çÇÑ º¼·ý°ú ÆÐŰ¡ ¿É¼ÇÀ¸·Î Á¦°øµË´Ï´Ù. Çϱ⿡
ÆÁÀÇ ¸î °¡Áö ¿¹°¡ ÀÖ½À´Ï´Ù. ¾î¶² ÆÁÀÌ ¾î¶² ¿ëµµ¿¡ °¡Àå ÀûÇÕÇÑÁö ±Ã±ÝÇϽøé ÀúÈñ Hamilton¿¡°Ô ¿¬¶ôºÎʵ右´Ï´Ù.
|
|
|
|
±Ô
°Ý |
ZEUS
|
ZEUS
LT
|

|

|
The ZEUS pipetting
channel includes an
integrated Z-Axis with
built-in aspirate and
dispense algorithms
that coordinate movements,
liquid classes, container
geometries, and error
handling. The ZEUS family
of pipetting modules
is designed for integration
into instrumentation
requiring on-board pipetting.
They perform single
sample transfers and
multiple dispenses (e.g.,
aliquoting) from 1 ¥ìL
to 1 mL with the highest
precision and accuracy.
The ZEUS Pipetting Modules
utilize Hamilton¡¯s
revolutionary air displacement
pipetting technology
and CO-RE¢â (compressed
O-ring expansion) tips.
|
The ZEUS LT pipetting
channel includes all
critical pipetting functions
and quick mounting hardware
for connection to an
existing Z-Axis. The
ZEUS family of pipetting
modules is designed
for integration into
instrumentation requiring
on-board pipetting.
They perform single
sample transfers and
multiple dispenses (e.g.,
aliquoting) from 1 ¥ìL
to 1 mL with the highest
precision and accuracy.
The ZEUS Pipetting Modules
utilize Hamilton¡¯s
revolutionary air displacement
pipetting technology
and CO-RE¢â (compressed
O-ring expansion) tips.
|

|
|
|
ZEUS
|
ZEUS LT
|
Dimension |
|
|
Straight
configurations:
|
25 x 205 x 337 mm
|
17 x 100 x 283 mm
|
Folded
configurations:
|
45 x 118 x 337 mm
|
NA
|
Right angle
configuration:
|
161 x 102 x 337 mm
|
NA
|
Weight: |
1100 g |
410 g
|
z-Drive |
|
|
Maximum
z-Excursion: |
180 mm |
NA
|
Resolution
z-Axis:
|
0.1 mm |
NA
|
Maximum
Speed z-Axis:
|
350 mm/s |
NA
|
Pipetting
Drive |
|
Volume
Range: |
1 ¥ìL – 1000 ¥ìL
|
Resolution:
|
0.1 ¥ìL
|
Maximum
Speed:
|
150 mm/s corresponding
to 2¡¯500 ¥ìL/s
|
Pipetting Mode: |
Single and aliquot dispensing |
Process
Security: |
Tip presence sensor
|
|
Pressure-based and capacitive
Liquid Level Detection (cLLD
and pLLD)
|
|
Qualitative Pipetting
Monitoring (QPM)
|
|
Anti-Droplet Control
(ADC)
|
Operating
Data |
|
Power requirement:
|
48 VDC ± 5%, 1.8
A
|
Temperature
range:
|
18°C – 32°C
|
Relative
humidity:
|
40% – 80% (non-condensing)
|
Noise level:
|
< 60 dBA, Indoor
use only
|
Storage
and Transportation |
|
Temperature
range:
|
-25¡É to +70¡É
|
Relative
humidity:
|
40% – 80% (non-condensing,
indoors)
|
Communication |
|
|
RS232:
|
NA
|
Full duplex, STX ETX
or CR-LF protocol
|
CAN:
|
Hamilton protocol
|
Hamilton protocol
|
Selectable
baud rate:
|
125, 500 kBaud (others
on request)
|
19¡¯200 or 38¡¯400
|
Device
Addressing:
|
Up to 31 modules on a
single CAN bus
|
Up to 31 modules in single
CAN bus Up to 32 modules
with RS232
|
|
Disposable Tip Size |
Pipetting Volume
|
Accuracy |
Precision |
10 µL
|
1 µL
|
5.0% |
4.0% |
|
5 µL
|
2.5%
|
1.5% |
|
10 µL
|
1.5% |
1.0% |
50 µL |
1 µL
|
5.0% |
4.0% |
|
5 µL
|
2.5% |
1.5% |
|
50 µL
|
2.0% |
0.75% |
300 µL |
10 µL
|
5.0% |
2.0% |
|
50 µL
|
2.0% |
0.75% |
|
300 µL
|
1.0% |
0.75% |
1000 µL |
10 µL
|
7.5% |
3.5% |
|
100 µL
|
2.0% |
0.75% |
|
1000
|
1.0% |
0.75% |
*Pipetting specifications were determined
gravimetrically using a high precision
balance and strictly controlled environmental
conditions: test temperature: 20 ±
2°C, relative humidity: 50% ±
5%, test liquid temperature range: ¡Â±
0.5°C of room temperature; balance
used: Mettler Toledo MX5.
The measurements were done with Hamilton
Verification Solution (deionized water
with 0.1% NaCl and 0.01% Tween detergent)
using standard CO-RE conductive tips.
A new tip was used for each pipetting
cycle (aspiration and dispense). At
least 10 points were taken for each
volume and pipetting module. Volumes
>20 ¥ìL were dispensed in jet mode.
Volumes ¡Â20¥ìL were dispensed in surface
mode. Results may vary using other liquid
or environmental conditions.
|
|
|
ÁÖ¹®Á¤º¸ |
Air Displacement Pipette Modules ; Hamilton Z-Excursion Universal Sampler (ZEUS) is a fully automated, self-contained, and ready-to-go pipetting module for integration into Diagnostics and Life Science instruments. It is based on Hamilton¡¯s revolutionary air displacement pipetting technology and uses disposable tips to avoid carry-over.The module is equipped with Qualitative
Pipette Monitoring (QPM) which ensures precise and secure pipetting.

ZEUS Channels
|
|
ZEUS Pipetting Channel (Straight, Motor Back) |
800700
|
ZEUS Pipetting Channel (Straight, Motor Forward) |
800701
|
ZEUS Pipetting Channel (Right Angle) |
800740
|
ZEUS Pipetting Channel (Folded 180 degree, Motor Back) |
800741
|
ZEUS Pipetting Channel (Folded -180 degree, Motor Back) |
800742
|
ZEUS LT Pipetting Channel |
800880
|
ZEUS Accessories |
|
Holder for CO-RE tip rack |
800336
|
Tip ejection sleeve (1/pk) |
800337
|
CO-RE LT Adapter (1/pk) |
8007952
|
ZEUS Starter Kit |
|
Test platform ; includes Holder for the ZEUS module, and Communication box |
202977-0020
|
Holder for ZEUS module |
202977-0021
|
Communication box ; includes USB/Hamilton CAN converter, power supply, cables and software CD |
202977-0022
|
|
Disposable Tips ; Hamilton offers a wide range of pipette tips to solve a variety of common automation challenges. Conductive, non-conductive, washable, slim and piercing tips are available in a variety for different volumes and packaging options. Below is an example of some off the shelf tips. Contact Hamilton to discuss which tips are most appropriate for your application.

10 ¥ìL tip |
non-filtered
|
conductive
|
60 racks of 96
|
235900-ZEUS
|
10 ¥ìL tip |
filtered
|
conductive
|
60 racks of 96
|
235901-ZEUS
|
50 ¥ìL tip |
non-filtered
|
conductive
|
60 racks of 96
|
235966-ZEUS
|
50 ¥ìL tip |
filtered
|
conductive
|
60 racks of 96
|
235948-ZEUS
|
300 ¥ìL tip |
non-filtered
|
conductive
|
60 racks of 96
|
235902-ZEUS
|
300 ¥ìL tip |
filtered
|
conductive
|
60 racks of 96
|
235903-ZEUS
|
300 ¥ìL slim tip |
non-filtered
|
conductive
|
40 racks of 96
|
235806-ZEUS
|
300 ¥ìL slim tip |
filtered
|
conductive
|
40 racks of 96
|
235647-ZEUS
|
1000 ¥ìL tip |
non-filtered
|
conductive
|
40 racks of 96
|
235904-ZEUS
|
1000 ¥ìL tip |
filtered
|
conductive
|
40 racks of 96
|
235905-ZEUS
|
|
|
|
|
|
±ÍÇÏÀÇ
¼º°øÀûÀÎ ¿¬±¸°³¹ßÀÇ µ¿¹ÝÀÚ°¡ µÇ°Ú½À´Ï´Ù.
|
18/10/12
|
|