JL350-2J ´ë±Ô¸ð Æ©ºê¿¬µ¿½Ä Á¤·®ÆßÇÁ

[JL350-2J Large Flow Peristaltic Tubing Pump]

AC ¸ðÅÍ, Á֯ļö º¯Á¶ Äܵå·Ñ
ȸÀü¼Óµµ : 30~350 rpm, ¿ªÈ¸Àü,
À¯·®¹üÀ§ : 1.3~35 Liter/min
ÆßÇÁÇìµå : KZ48

 

  °³ ¿ä

JL350-2J °ø¾÷¿ë Æ©ºê¿¬µ¿½Ä Á¤·®ÆßÇÁ´Â ³ôÀº À¯·®À¸·Î ÀϰýÀ¯Ã¼À̼ۿ¡ ÀûÇÕÇϸç,  AC ¸ðÅÍ¿Í Á֯ļö º¯Á¶±â¿¡ ÀÇÇØ ȸÀü¼Óµµ¸¦ Á¦¾îÇÒ ¼ö ÀÖ´Ù.

ÃÖ´ë 35 Liter/min ±îÁö À¯·®Á¶ÀýÀÌ °¡´ÉÇϸç, Åõ¸íÇÑ Àü¸éÄ¿¹ö¸¦ ÅëÇØ ÆßÇÁÇìµåÀÇ ÀÛµ¿»óŸ¦ °üÂûÇÒ ¼ö ÀÖ´Ù.

ÆßÇÁÀÇ È¸Àü¼Óµµ¿Í ȸÀü¹æÇâ, ½ÃÀÛ/Á¤Áö ±â´ÉÀº ¸âºê·¹ÀΠŰÆÐµå¿¡ ÀÇÇØ ¼öµ¿Á¶ÀÛÇϰųª ¿ÜºÎÁ¦¾î ÀÎÅÍÆäÀ̽º¸¦ ÅëÇØ ÀÚµ¿À¸·Î Á¦¾îÇÒ ¼ö ÀÖ´Ù.

Á¶ÀÛÀÌ °£´ÜÇÏ°í Æí¸®ÇÏ´Ù.

 

  Æ¯ ¡ 

Mainly used in industrial application. But also suitable for laboratory application where the high flow rate is required.

JL350-2J peristaltic pump is ideal for high flow rates fluid transfer. The flow rate is from 1.3L/min to 15mL/min. The pump is driven by the AC motor, and the speed is controlled through the frequency converter. This pump is mainly for industrial application.

High-capacity pump

Combine special convex rollers with concave compression block to run stably and prolong tubing life.

Variable frequency speed control to AC motor with creeper gear

Adjustable occlusion

Strong drive

Pump head operation is visible through transparent front cover

 

  ±Ô °Ý

Speed

:

30~350 rpm, CW/CCW

Speed resolution

:

0.6 rpm
Speed control

:

Frequency converrtor, external signal control and communication control available
Display

:

LCD for running information
External control

:

Start/stop and cw/ccw control

 

 

 

0~5V, 0~10V, 4~20mA & 0~10KHz linear control
Communication interface

:

RS485 or RS232

Memory function

:

Storing the running parameter automatically

Power supply

:

AC220V±10%/50-60 Hz
Power consumption

:

¡Â400W

Operating condition

:

Temperature; 0~40¡É
 

 

 

Relative humidity; <80%
Dimensions

:

417 L x 401 W x 321 mmH
Weight

:

32 kg
IP rating

:

IP55

 

  ÁÖ¹®Á¤º¸

Drive

Pump head

Tubing

Flowrates(L/min)

Weight(kg)

JL350-2J
(05.02.34A)

KZ48

88#

1.3~15

32

92#

3~35

 

  ±â¼úÀÚ·á

JL350-2J Large Flow Rates Pump External Control Function (Release Time£º2016-12-23)

External Control Function ; External analog signal controls the speed: The keys on the panel of frequency converter are invalid by setting the parameters (needs unlock). The speeds are controlled by external control terminals.485 communication interface: By setting the parameters (needs unlock) the master computer can control the pump directly by communication interface.

Note; The frequency converter has many parameter setting items. To avoid misoperation we lock the parameter settings by password.We set the max. frequency of the frequency converter is 65 Hz and the max. speed is 370 rpm. If other parameters setting are needed please ask for password from our company. But we won't take any responsibility if damage occurs because of parameters changing.   

 

Basic operation of the Frequency Converter for JL350-2J (Release Time£º2016-12-23) 

The LED display of frequency converter lights when the power supply switches on. But the pump is in stopping status.Run

/stop: Press [Run/Stop] key, the [Run] indicator lights and the pump runs. Press the [Run/Stop] key again the pump stops.Speed Adjustment: Press Speed Adjustment/ Data Input Keys 2 to change the speed of the pump. The LED displays the value of the frequency. The actual speed (rpm) is about 5.8 times of frequency value.

Direction: Press the [MODE/RESET] key continuously till the LED displays [Frd] when the [FWD] indicator which is in the left side of LED screen lights. Press the Speed Adjustment/ Data Input Keys 2, the LED displays [REV]. The [REV] indicator lights at the same time and the motor rotates reversely. When the [REV] indicator which is in the left side of the LED screen lights, switch to [FWD] mode in the same way.

Display Convert: Press the [MODE/RESET] key continuously can show the following parameters alternatively: F: setting the frequency; H: the actual running frequency; A: the current of the motor.

Frequency Converter Troubleshooting: Frequency converter has many warning and protective functions. The motor will stop automatically when the pump is in abnormal status. Eliminate the abnormal status and press the [MODE/RESET] key the pump can work continuously. The letters or the symbols on the LED display show the information of abnormal status. For details please see the <SE Series Frequency Converter Operating Manual >

 

 