[Peristaltic
Pump
Accessories] |
|
|
|
|
|
|
|
Dispensing Controller |

|
Dispensing time |
:
|
0-99.99S |
Pause time |
:
|
0-99.99S |
Time resolution |
:
|
0.01S |
Work mode |
:
|
Single or multiple |
Internal count range |
:
|
0-999, count up or count down |
External count range |
:
|
999999£¬0 means unlimited cycle |
External Start/Stop |
:
|
Open circuit |
Memory function |
:
|
Repower the pump, user can choose whether to continue in accordance with the
state before the power-down |
Power supply |
:
|
AC 220V/5W |
|
Type |
Product
code
|
Function |
FK-1C |
05.49.25A
|
Dispensing controller can be equipped with many peristaltic pumps, gear pumps to
realize dispensing automatically. |
|
|
|
Foot
Switch |

|
Type |
Product
code
|
Connector
|
Applicable
|
Function |
JK-1 |
05.49.20A
|
DB-9
|
Peristaltic Pumps
|
Gated: Pump stops when it is powered on. Pump runs when press
down the footswitch; and pump stops when release the footswitch. Trigger:
Pump stops when it is powered on. Pump runs when footswitch is pressed once, and
pump will stop when footswitch is pressed again.
|
JK-2 |
05.49.20B
|
DB-9
|
Dispensing Controller
|
Trigger:
Pump stops when it is powered on. Pump runs when footswitch is pressed once, and
pump will stop when footswitch is pressed again.
|
JK-3 |
05.49.20C
|
DB-15
|
Peristaltic Pumps
|
Gated: Pump stops when it is powered on. Pump runs when press
down the footswitch; and pump stops when release the footswitch. |
JK-4 |
05.49.20D
|
DB-9
|
LSP Syringe Pumps
|
Gated: Pump stops when it is powered on. Pump runs when press down the
footswitch; and pump stops when release the footswitch. Trigger: Pump
stops when it is powered on. Pump runs when footswitch is pressed once, and pump
will stop when footswitch is pressed again. |
JK-5 |
05.49.20E
|
DB-15
|
TJ Syringe Pumps
|
Trigger: Pump stops when it is powered on. Pump runs when
footswitch is pressed once (press down and release), and pump will stop when
footswitch is pressed again. |
JK-6 |
05.49.20F
|
None
|
TS Syringe Pumps
|
Trigger: Pump stops when it is powered on. Pump runs when
footswitch is pressed once (press down and release), and pump will stop when
footswitch is pressed again. |
JK-8 |
05.49.20H
|
9-pin
|
YT600-1J
|
|
JK-9 |
05.49.20I
|
9-pin
|
WT600-3J
|
|
JK-10 |
05.49.20J
|
9-pin
|
WT600-4F
|
|
JK-11 |
05.49.20K
|
DB-15
|
Peristaltic Pumps
|
|
JK-12 |
05.49.20L
|
DB-9
|
Peristaltic Pumps
|
|
JK-13 |
05.49.20M
|
None
|
FK-100Z
|
|
JK-14 |
05.49.20N
|
BNC
|
LLP01-100
|
|
|
|
|
External
Control Interface |

|
Type |
Product
code
|
Connector
|
BQ50-1J, WT3000-1JA,
BT100-2J, BT100-1F, WT3000-1FA,
BT300-2J, BT300-1F, WT3000-1JB,
BT600-2J, WT600-2J, WT3000-1FB,
WT600-1F
|
0~5 V |
05.49.31A
|
DB-15
|
0~10 V |
05.49.31B
|
DB-15
|
4~20 mA |
05.49.31C
|
DB-15
|
0~10 kHz |
05.49.31D
|
DB-15
|
RS-485 |
05.49.31E
|
DB-15
|
WK-01 |
-
|
-
|
Change (4-20mA, 0-5V,
0-10V) on the basis of standard
analog external control
module on the increase in
internal and external control
conversion.
|
Wk-02
|
-
|
-
|
Switching control start
and stop supporting OEM100J-75
|
WK-03 |
-
|
-
|
Switching control start
and stop supporting OEM100J-75
|
WK-04 |
-
|
-
|
Switching control peristaltic
pump (except aeronautical
product plug interfaces)
start and stop, stop short,
disconnected operation
|
WK-05 |
-
|
-
|
Switching control peristaltic
pump WT600-3J, WT600-4F
start and stop
|
WK-06 |
-
|
-
|
Switching control start
and stop, fault alarm output
by the extraction module
|
WK-07 |
-
|
-
|
WK-04 module controls
the start and stop logic
is inverted; short run,
stop off
|
WK-08 |
-
|
-
|
External control only
controls the start and stop
buttons control the speed
of the internal control,
5V stopped, suspended the
operation according to the
original state
|
WK-09 |
-
|
-
|
External control only
controls the start and stop
buttons control the speed
of the internal control,
24V stopped, suspended the
operation according to the
original state
|
WK-10 |
-
|
-
|
External control switch
start and stop and direction
control, speed control button
internal, supporting BT100-2J-12
& YZ1515X
|
WK-11 |
-
|
-
|
Increase external control
switch function on the basis
of external control 0-10V
|
WK-12 |
-
|
-
|
And supporting the use
of BT100-2J-18, DB15 connected
to drive external control
interface, DB9 pin 2 Take
0-10V negative, positive
needle 5 then 0-10V
|
WK-17 |
-
|
-
|
Adaptation LSP02-1B-1,
by switching control and
direction of the pump start
and stop.
|
WK-18 |
-
|
-
|
Supporting BT100-2J-21
|
WK-19 |
-
|
-
|
Supporting the use TJ-3A-5,
switch control, external
control start and stop and
direction control
|
|
|
|