LSP
ÁÖÀÔ/ÈíÀÔ½Ä
Á¤¹Ð
ÁÖ»ç±âÆßÇÁ |

|
[LSP
Series
Syringe
Pumps] |
|
|
|
|
|
|
|
|
|
|
|
±Ô
°Ý |
+
È®´ëÇÑ ±×¸²º¸±â-> |
LSP02-1B
 |
LSP10-1B
 |
LSP01-1BH

|
LSP01-1C

|
Working Mode |
Infusion/Withdrawal |
Push/Full
|
Channel |
2 |
10
|
1
|
2
|
Syringe |
10 uL
~ 60 mL
|
10 uL
~ 10 mL
|
10 uL
~ 100 mL
|
10 uL
~ 10 mL
|
Stroke |
140 mm |
Pusher
Advance |
0.156
um/step
|
Linear
Speed |
5 um/min~130
mm/min
|
5um/min~65mm/min
|
Linear
Resolution |
5 um/min
|
Linear
Accuracy |
¡Â±0.5%
when ¡Ã30% of pump stroke |
Linear Force |
¡Ã18 kg (40 lbs) |
¡Ã45 kg (99 lbs) |
¡Ã9 kg (20 lbs) |
Syringe
Selection |
Built-in
syringe branched, size and
inner diameters |
Syringe
Defined |
Can store
four user-defined syringe
inner diamerters |
Flowrate
Calibration |
Improve
flowrate accuracy |
Running
Parameter |
Infusion/withdrawal
volume, infusion/withdrawal time, pause
time, etc |
Display
Setting |
Display
volume, flowrate or linear
speed |
Power-off
Memory |
Storing
the running parameters automatically |
State
Output |
OC gate
signal to indicate start/stop
and direction |
Control
Input |
Falling
edge or TTL signal to control
Start/Stop
|
Communication |
RS-485
|
Diemensin |
280Lx210Wx140mmH
|
280Lx330Wx140mmH
|
280Lx250Wx140mmH
|
280Lx220Wx140mmH
|
Weight |
4.3 kg
|
5.3 kg
|
6.3 kg
|
3.6 kg
|
Power |
AC 90-260V/20W
|
AC 90-260V/25W
|
AC 90-260V/15W
|
|
Syringe |
Diameter (mm) |
LSP02-1B (uL/min~mL/min) |
LSP10-1B (uL/min~mL/min) |
LSP01-1C (uL/min~mL/min)
|
10 uL |
0.50 |
0.001-0.0255 |
0.001-0.0255 |
0.001-0.0128 |
25 uL |
0.80 |
0.0025-0.0653 |
0.0025-0.0653 |
0.0025-0.0327 |
50 uL |
1.10 |
0.0048-0.1235 |
0.0048-0.1235 |
0.0048-0.0618 |
100 uL |
1.60 |
0.0101-0.2614 |
0.0101-0.2614 |
0.0101-0.1307 |
250 uL |
2.30 |
0.0208-0.5401 |
0.0208-0.5401 |
0.0208-0.2701 |
500
uL |
3.25 |
0.0415-1.0784 |
0.0415-1.0784 |
0.0415-0.5392 |
1.0 mL |
4.72 |
0.0875-2.2747 |
0.0875-2.2747 |
0.0875-1.1373 |
2.0 mL |
9.00 |
0.3181-8.2702 |
0.3181-8.2702 |
0.3181-4.1351 |
5.0 mL |
13.10 |
0.6739-17.522 |
0.6739-17.522 |
0.6739-8.7608 |
10 mL |
16.60 |
1.0821-28.135 |
1.0821-28.135 |
1.0821-14.068 |
20 mL |
19.00 |
1.4176-36.859 |
- |
-
|
30 mL |
23.00 |
2.0774-54.012 |
- |
-
|
60 mL |
29.14 |
3.3346-86.699 |
- |
-
|
|
Syringe |
Diameter
(mm) |
LSP01-1C
(uL/min~mL/min)
|
Outlet Pressure (Mpa) |
2.5
mL |
4.79 |
0.0901-2.3426 |
19.48 |
8.0
mL |
9.53 |
0.3567-9.2730 |
5.05 |
20
mL |
19.13 |
1.4371-37.3648 |
1.25 |
50
mL |
28.6 |
3.2121-83.5152 |
0.56 |
100
mL |
34.9 |
4.7831-124.361 |
0.37 |
|
|
|
ÁÖ¹®Á¤º¸ |
Model |
Product
code
|
Channel
|
Pusher
Advance |
Linear Force |
LSP02-1B |
050344A
|
2
|
0.156
um/step
|
¡Ã18 kg (40 lbs) |
LSP10-1B |
050346A
|
10
|
0.156
um/step
|
¡Ã18 kg (40 lbs) |
LSP01-1BH
|
050343A
|
1
|
0.156
um/step
|
¡Ã45 kg (99 lbs) |
LSP01-1C
|
050342A
|
1
|
0.156
um/step
|
¡Ã9 kg (20 lbs) |
|
LSP01-1BH High Pressure Syringe Pump
 
SS
syringe |
Tube
length
|
Stroke
length
|
Outer
diameter |
Inner
diameter |
Total
length
|
8
mL |
170
mm
|
110.5
mm
|
14
mm
|
9.53
mm |
203 mm
|
20
mL |
120
mm
|
68.4
mm
|
22
mm
|
19.13
mm |
144 mm
|
50
mL
|
140
mm
|
76.8
mm
|
32
mm
|
28.6
mm |
165 mm
|
100
mL
|
170
mm
|
107.0
mm
|
38
mm
|
34.9
mm |
210 mm
|
|
LSP01-1C Push/Full
Syringe Pump
 
|
|
|
±â¼úÀÚ·á |
LSP02(10)-1B Syringe
Pump External control
port (Release Time£º2017-01-06)
Pin definition
2 Directional
output, OC gate output,
open – infusion, close
– withdrawal (stays
open when stopped) 3
COM, ground ref. 4
Gate, TTL input,
change from high to
low - starts; when running
stays low, change to
high - stops 7 Run
indicator, OC gate output,
close - stopped, open
– running 8 Trigger,
TTL input, falling edge
start/stop pump, e.g.
footswitch 9 Reverse
Direction, TTL input,
normally low; change
to high reverses. (Only
applies to infuse/ withdraw
mode)
|
LSP02(10)-1B Syringe
Pump RS485 setup (Release
Time£º2017-01-06)
The RS485 connections
are made through terminal
connectors, located
on the rear panel. A
single PC can control
up to 30 pumps. When
controlled by a PC each
pump must be assigned
an individual address.
When controlled via
RS485 the pump will
still respond to keypad
commands. All RS485
commands settings, similar
to keypad settings,
are stored in EEPROM.
When RS485 is enabled,
RS485 interface will
display communication
address and band rate.

The communication
address is from 1 to
30. The default address
is 1. The band rate
is 1200 bps, 2400 bps
and 9600 bps. The default
band rate is 2400 bps.
RS485 format: 1 start
bit, 8 data bits, 1
even parity, 1 stop.
For detailed RS485 commands
please see <Longer¡¯s
RS485 Protocol for LSP>.
In parameters setting
interface, press and
turn RES to highlight
the RS485 line. Set
RS485 enabled. The LCD
displays communication
address and band rate.
Turn RES to make the
address highlighted.
Press RES to highlight
the numerical value.
Turn RES to set the
communication address.
Press RES again to confirm
and save the setting.
Turn RES to highlight
the band rate. Press
RES to make the numerical
value highlighted. Turn
RES to select the band
rate. Press RES again
to confirm and save
the selection.
|
LSP02(10)-1B Syringe
Pump External control
function (Release
Time£º2017-01-06)
External control
function, including
run/stop control input
and direction control
input can be enabled
or disabled.
1. In parameters
setting interface, press
and turn RES to highlight
the external control
line. 2. Press RES
to highlight the parameter.
Turn RES to select the
needed parameter. Disable:
disable the external
control input, that
is, the input is invalid. TTL:
TTL input controls the
start and stop of the
pump. Trigger: falling
edge input controls
the start and stop of
the pump.
|
LSP02(10)-1B Syringe
Pump Calibration (Release
Time£º2017-01-06)
The flowrate can
be calibrated for more
accurate dispense volume.
1. In parameters
setting interface, press
and turn RES to highlight
the Calibration line.
Press RES to enter calibration
interface. 2. Testing
time line is highlighted.
Press RES to highlight
the numerical value
position. Turn RES to
select the testing time.
The testing time is
from 0.5 minutes to
60 hours. Press RES
to confirm. 3. Press
Run/Pause key to start
the testing. After testing,
turn RES to highlight
the testing volume line.
Press RES to highlight
the numerical value
position. Enter the
actual volume from the
membrane keypad. Press
RES to confirm. 4.
After calibration, the
linear speed of the
Pusher Block changes
to increase the accuracy
of the dispense volume.
|
LSP02(10)-1B Dual
Channels Syringe Pump
Pause time setting (Release
Time£º2017-01-06)
In infusion/withdrawal
mode, the pause time
is set in infusion parameters
setting interface. In
withdrawal mode, the
pause time is set in
withdrawal parameters
setting interface. In
continuous mode, the
pause time need to be
set both in infusion
mode interface and in
withdrawal mode interface.
The unit of pause time
is sec, i.e. second,
and the range of pause
time is from 0 to 9999sec
in steps of 0.1sec
|
LSP02(10)-1B Dual
Channels Syringe Pump
Flowrate setting (Release
Time£º2017-01-06)
In parameters setting
interface, turn and
press RES to highlight
the infusion flowrate
or withdrawal flowrate
setting line. Press
RES to make the numerical
value position highlighted.
Enter the flowrate required
from the membrane keypad.
Press RES to set flowrate
unit. Turn RES to scroll
through the list and
press RES to select
the unit required. Possible
flowrate units are µl
/h, µl/m, ml/h,
ml/m. The highlighted
display indicates that
this parameter can be
changed.
Note: If the number
entered exceeds the
maximum flowrate possible
then the pump prompts
the maximum feasible
flowrate at the Time
position. To continue
enter a flowrate smaller
than the maximum.
|
LSP02(10)-1B Dual
Channels Syringe Pump
Volume setting (Release
Time£º2017-01-06)
In parameters setting
interface, turn and
press RES to highlight
the infusion volume
or withdrawal volume
setting line. Press
RES to make the numerical
value position highlighted.
Enter targeted volume
from the membrane keypad.
Press RES to set volume
unit. Turn RES to scroll
through the list and
press RES to select
the unit required. Possible
volume units are µl
and ml, i.e. microliter
and milliliter. The
highlighted display
indicates that this
parameter can be changed.
Note: When the volume
setting is zero, Infusion
or Withdrawal modes.
Volume = 0 is interpreted
as no volume and the
pump will run until
manually stopped or
a stall occurs. The
LCD will display the
flowrate setting. Infusion/withdrawal,
Withdrawal/infusion
and Continuous modes.
A volume setting
must be entered. If
no volume is entered
the motor does not run.
|
|
|
LSP01-1BH
ÁÖ»ç±âÆßÇÁ ¾Ð·Â½ÃÇè
|
|
|
|
|
|
±ÍÇÏÀÇ
¼º°øÀûÀÎ ¿¬±¸°³¹ßÀÇ µ¿¹ÝÀÚ°¡ µÇ°Ú½À´Ï´Ù.
|
20/05/27
|
|