Á¤¹ÐÁ¤·®ÆßÇÁ
À¯Ã¼Ãë±ÞÁ¦Ç°
Å©·Î¸¶Åä±×·¡ÇÇ
¿¬±¸½ÇÇè±âÀÚÀç

 

 

 

L0107  ¸¶ÀÌÅ©·Î ÁÖ»ç±âÆßÇÁ

[L0107 Series Micro Syringe Pumps]

TJ-1A/L0107-1A ÁÖÀÔ½Ä 1-ä³Î ¸¶ÀÌÅ©·Î ÁÖ»ç±âÆßÇÁ
TS-1A/L0107-1A ÁÖÀÔ½Ä 4-ä³Î ¸¶ÀÌÅ©·Î ÁÖ»ç±âÆßÇÁ
TJ-2A/L0107-2A ÁÖÀÔ/ÈíÀÔ½Ä 1-ä³Î ¸¶ÀÌÅ©·Î ÁÖ»ç±âÆßÇÁ
TS-2A/L0107-2A ÁÖÀÔ/ÈíÀÔ½Ä 4-ä³Î ¸¶ÀÌÅ©·Î ÁÖ»ç±âÆßÇÁ

 

  °³ ¿ä

TJ ÁÖ»ç±âÆßÇÁ´Â ¼³Ä¡¿Í ÀÛµ¿ÀÌ °£ÆíÇÑ ³ôÀº Á¤¹Ðµµ¿Í ÄÄÆÑÆ®ÇÑ »çÀÌÁîÀÇ 1-ä³Î ¸¶ÀÌÅ©·Î ÁÖ»ç±â ÆßÇÁ·Î¼­ ¸¶ÀÌÅ©·Î¸®ÅÍ(µL) ´ÜÀ§ÀÇ ÁÖ»ç±â¸¦ ÀåÂøÇÒ ¼ö ÀÖ´Ù. Á¤¹ÐÇÏ°í ³ôÀºÀçÇö¼ºÀ» Á¦°øÇÏ¸ç ³ÐÀº À̵¿¼Óµµ ¹üÀ§ (7.9 µm/min - 79.4 mm/min)´Â ´Ù¾çÇÑ ¿ä±¸Á¶°ÇÀ» ¸¸Á·½Ãų ¼ö ÀÖ´Ù. ¼öÁ÷ ¶Ç´Â ¼öÆòÀ¸·Î ¼³Ä¡ÇÒ ¼ö ÀÖ´Â ±¸Á¶´Â Çö¹ÌÁ¶ÀÛ±â(micromanipulator) ¶Ç´Â Á¤À§Á¶ÀÛ±â (stereotaxic) µî ´Ù¾çÇÑ »ý¹°ÇÐÀûÀÎ ¿¬±¸¿¡ Àû¿ëÇÒ ¼öÀÖ´Ù.
TSÁÖ»ç±âÆßÇÁ´Â ¼³Ä¡¿Í ÀÛµ¿ÀÌ °£ÆíÇÑ ³ôÀº Á¤¹Ðµµ¿Í ÄÄÆÑÆ®ÇÑ »çÀÌÁîÀÇ 4-ä³Î ¸¶ÀÌÅ©·Î ÁÖ»ç±â ÆßÇÁ·Î¼­, ¹Ð¸®¸®ÅÍ(mL) Ç¥ÁØ ÁÖ»ç±â¸¦ ÀåÂøÇÒ ¼ö ÀÖ´Ù. Á¤¹ÐÇÏ°í ³ôÀºÀçÇö¼ºÀ» Á¦°øÇÏ¸ç ³ÐÀº À̵¿¼Óµµ ¹üÀ§(7.9 µm/min - 79.4 mm/min)´Â ´Ù¾çÇÑ ¿ä±¸Á¶°ÇÀ» ¸¸Á·½Ãų ¼ö ÀÖ´Ù. ±¸µ¿ºÎ(driver)¿Í Á¦¾îºÎ(controller)°¡ º°µµ·Î µÇ¾î ÀÖÀ¸¸ç, ÄÄÆÑÆ®ÇÑ ±¸Á¶·Î µÇ¾î ÀÖ´Ù. ¼öÁ÷ ¶Ç´Â ¼öÆòÀ¸·Î ¼³Ä¡ÇÒ ¼ö ÀÖ´Â ±¸Á¶À̱⠶§¹®¿¡ Çö¹ÌÁ¶ÀÛ±â(micromanipulator) ¶Ç´Â Á¤À§Á¶ÀÛ±â (stereotaxic) µî ´Ù¾çÇÑ »ý¹°ÇÐÀûÀÎ ¿¬±¸¿¡ Àû¿ëÇÒ ¼öÀÖ´Ù.
´ëÇü LCD È­¸é¿¡¼­ ȸÀü½ºÀ§Ä¡¿Í ¸âºê·¹ÀÎŰÆÐµå¸¦ ÀÌ¿ëÇÏ¿© ÆÄ¶ó¸ÞÅÍÀÇ ¼³Á¤À» °£ÆíÇÏ°Ô ÇÒ ¼ö ÀÖ´Ù

 

  Æ¯ ¡

Working Mode : Infusion or infusion/withdrawal
Parameters Setting : The parameters of each channel can be different.
Running Control : Each drive unit can be controlled separately, or four drive units can be controlled to run simultaneously or run at different time
Channel Copy : All drive units can be run according to the parameters of one drive units of them
Delaying Startup : Delaying startup time of each channel can be controlled separately
Memory Function : Select resume operation or remain stopped when power turns after an interruption
Block Protection : When one drive unit stops accidently, the system will warm and stop
Working Mode: Infusion
External Control : Start/stop input control signal which is pulse mode to switch the states of start and stop
Communication : Realize computer control through RS485 communication interface

 

¡¡

Main Functions for Each Channel

Syringe Selection : The syringe can be selected in the manufacture table which includes manufacturer,
   material and size
User-Defined Glass Syringe : Save 4 inner diameter of user-defined glass syringe barrel
Parameters Setting : Set dispensing volume, infusion time, pause time and copy number
Display Mode Selection : Different parameters (column, flow rate, linear speed)can be selected
   in the main display inter face
Fast Forward & Fast Reverse : Infusion at the max. speed
Calibration : Acquire accurate volume through calibration

 

  ±Ô °Ý

  + È®´ëÇÑ ±×¸²º¸±â ->

 TJ-1A/L0107-1A
 

 TS-1A/L0107-1A
 

 TJ-2A/L0107-2A
 

TS-2A/L0107-2A

Working Mode

 Infusion

Infusion/Withdrawal

Channel

1

1~4

1

1~4

Syringe

5 uL ~ 1.0 mL

Stroke

70 mm

Pusher Advance

0.165 um/step

Linear Speed

7.94 um/min ~ 79.4 mm/min

Linear Resolution

7.94 um/min

Linear Accuracy

¡Â±0.5% when ¡Ã30% of pump stroke

Linear Force

¡Ã2 kg (4.4 lbs)

Syringe Selection

Built-in syringe branched, size and inner diameters

Syringe Defined

Can store four user-defined syringe inner diamerters

Flowrate Calibration

Improve flowrate accuracy

Running Parameter

Dispensin volume can be each channel,
all channel use the parameters of the specified channel

Start setting

Each drive unit can be started seperately,
simultanously or according to each delay time

Display Setting

Display volume, flowrate or linear speed

Power-off Memory

Select keeping previous state or resetting parameters when power on

Forwarard/backward

Infuse or withrawal liquid at full speed

State Output

2 OC gate signal to indicate start/stop and direction

Control Input

3 TTL signal to control start/stop, fast forwarard and fast backward

Communication

RS-485

Drive unit dimension

180L x 46W x 78 mmH

Drive unit weight

0.6 kg

Controller dimension

170Lx108Wx65mmH

235Lx178Wx74mmH

170Lx108Wx65mmH

235Lx178Wx74mmH

Controller weight

0.5 kg

0.8 kg

0.5 kg

0.8 kg

Power

AC 90-260V/10W

AC 90-260V/40W

AC 90-260V/10W

AC 90-260V/40W

Syringe

 Diameter(mm)

Flowrate (nL/min~uL/min) 

5 uL

0.35

0.764 - 7.64

10 uL

0.50

1.559 - 15.59

25 uL

0.80

3.991 - 39.91

50 uL

1.10

7.546 - 75.46

100 uL

1.60

15.96 - 159.6

250 uL

2.30

32.99 - 329.9

500 uL

3.25

65.87 - 658.7

1000 uL

4.61

132.5 - 1325

 

  ÁÖ¹®Á¤º¸

Model

Product code

Channel

Pusher Advance

Linear Force

TJ-1A/L0107-1A

050310A/050300A

1

0.165 um/step

¡Ã2 kg (4.4 lbs)

TS-1A/L0107-1A

050315B/050300A

1~4

TJ-2A/L0107-2A

050311A/050301A

1

TS-2A/L0107-2A

050316B/050301A

1~4

TJ-4A/SL0104A-1A

050314A/050303A

1

3.048 um/step

¡Ã1 kg (2.2 lbs)

TJ-4A/SL0107A-1A

050314A/050304A

1

TJ-4A for Micromanipulator
??ãø?Úª??ñ¼ÞÒ?TJ-4A

 

  ±â¼úÀÚ·á

TJ-2A/L0107-2A ÁÖ»ç±âÆßÇÁ Á¶¸³

TJ-2A ÁÖ»ç±âÆßÇÁ À¯·®±³Á¤

TJ-2A ÁÖ»ç±âÆßÇÁ ºÐÁÖ¸ðµå Á¶ÀÛ

TJ-2A ÁÖ»ç±âÆßÇÁ ±âº»Á¶ÀÛ

TS-1A ÁÖ»ç±âÆßÇÁ ¸ÖƼä³Î µ¿½ÃÁ¶ÀÛ

TS-1A ÁÖ»ç±âÆßÇÁ ¿ÜºÎÁ¦¾î

TS-1A ÁÖ»ç±âÆßÇÁ ¸ÖƼä³Î Á¶µ¿

TS-1A ÁÖ»ç±âÆßÇÁ À¯·®±³Á¤

 

 

±ÍÇÏÀÇ ¼º°øÀûÀÎ ¿¬±¸°³¹ßÀÇ µ¿¹ÝÀÚ°¡ µÇ°Ú½À´Ï´Ù.

20/05/27